
____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com - MultiProx Controller Installation Manual 6000-900 Rev F 17 of 27
Switches are shown in the factory default position.
on off
on off
SW1
on off
SW2
on off
on off
on off
SWR - RED LED
on off
SW4
Figure 3
Note: Power down and power up again to
program changes made to SW1 through
SW4
Channel 8 - Beeper operation - "on" = reader beeps when a card is read, "off" = reader does not beep
Channel 7 - Beeper operation “
Channel 6 - Beeper operation “
Channel 5 - Beeper operation “
Channel 4 - Beeper operation “
Channel 3 - Beeper operation “
Channel 2 - Beeper operation “
Channel 1 - Beeper operation “
Channel 8 - Green LED operation - "on" = reader flashes Green LED when a card is read, "off" = does not flash Green LED
Channel 7 - Green LED operation “
Channel 6 - Green LED operation “
Channel 5 - Green LED operation “
Channel 4 - Green LED operation “
Channel 3 - Green LED operation “
Channel 2 - Green LED operation “
Channel 1 - Green LED operation “
Channel 8 - Red LED operation - "on" = reader LED is normally Red, "off" = reader LED is normally off
Channel 7 - Red LED operation “
Channel 6 - Red LED operation “
Channel 5 - Red LED operation “
Channel 4 - Red LED operation “
Channel 3 - Red LED operation “
Channel 2 - Red LED operation “
Channel 1 - Red LED operation “
Alternate Facility code, on = enabled, off = disabled
Card type 1030 = off, 1040 = on, 1050 = on
Card type 1030 = on, 1040 = off, 1050 = on
Not Used
Not Used
Main Facility Code Letter A = off, B = off, C = on, D = on
Main Facility Code Letter A = off, B = on, C = off, D = on
Main Facility Code Bit 8 - 2
8
(256) on = 1, off = 0 See Decimal to Binary conversion table Figure 9
Main Facility Code Bit 7 - 2
7
(128) See Decimal to Binary conversion table Figure 9
Main Facility Code Bit 6 - 2
6
(64) “
Main Facility Code Bit 5 - 2
5
(32) “
Main Facility Code Bit 4 - 2
4
(16) “
Main Facility Code Bit 3 - 2
3
(8) “
Main Facility Code Bit 2 - 2
2
(4) “
Main Facility Code Bit 1 - 2
1
(2) “
Main Facility Code Bit 0 - 2
0
(1) “
HSM Monitor Enable on = enabled, off = disabled
Channel Number selection 1 = off, 2 = off, 4 = on, 8 = on
Channel Number selection 1 = off, 2 = on, 4 = off, 8 = on
Not Used
Schlage 26 Bit Wiegand Output Option = on, 32 Bit Wiegand Output = off
Alternate Facility Code Letter A = off, B = off, C = on, D = on
Alternate Facility Code Letter A = off, B = on, C = off, D = on
Alternate Facility Code Bit 8 - 2
8
(256) on = 1, off = 0 See Decimal to Binary conversion table Figure 9
Alternate Facility Code Bit 8 - 2
7
(126) See Decimal to Binary conversion table Figure 9
Alternate Facility Code Bit 6 - 2
6
(64) “
Alternate Facility Code Bit 5 - 2
5
(32) “
Alternate Facility Code Bit 4 - 2
4
(16) “
Alternate Facility Code Bit 3 - 2
3
(8) “
Alternate Facility Code Bit 2 - 2
2
(4) “
Alternate Facility Code Bit 1 - 2
1
(2) “
Alternate Facility Code Bit 0 - 2
0
(1) “
Kommentare zu diesen Handbüchern