HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com - MultiProx Controller Installation Manual 6000-900 Rev F 5 of 27
Installation Procedure For Retrofitting an existing 708 or 808 Controller
1.Replace old 708/808 with new MultiProx Controller
1a. Locate the existing Schlage/Westinghouse (SE) Controller.
1b. Remove coax cables from Sensors, cables from door lock outputs, power supply and terminal connections.
Mark coax cables with Reader channel locations, and all other wires with their functions for future reference.
1c. Remove SE components and put aside. Replace the 708/808 Controller with the MultiProx Controller. The
mounting holes are located in the same positions as the SE Controller.
2. Install MultiProx Readers
2a. Locate existing Schlage/Westinghouse Sensor(s). Determine their type (back or side mounted). Verify that
the existing location is suitable for the MultiProx Reader. See Installation notes for mounting Readers and
MultiProx Reader dimensions - Figure 6.
2b. the coax cable from the SE Sensor. Remove the SE Sensors.
2c. Connect the MultiProx Reader to the coax cable (hand tight) and insulate the connector using electrical tape
or shrink tubing. Do not use wrenches or pliers to tighten the coax connectors.
2d. Mount the MultiProx Reader. Use the hardware that comes with the MultiProx Reader or use existing SE
hardware. For more information see the MultiProx Reader installation guide (5385-900).
3. MultiProx Reader and Wiegand connections - at the Controller
3a. Connect the coax cables to the MultiProx Controller. Note which channels are connected to each Reader
location. The Reader coax channel numbers are labeled on the top cover of the Controller. The Coax
connectors are the same type as a typical TV or cable TV connection that uses 75 ohm RG/6 coax cable.
The cable connectors are called “F” type and are commonly available in electrical supply stores as “F-56
crimp-on connectors for RG/6 cable”. A crimping tool is required. Follow the directions that come with the
connectors and crimp tools. Twist-on types are also available, but are less reliable.
3b. Connect the Wiegand interface cables using the supplied removable 6 pin terminal strips. Connect the
Wiegand interface cables to the Access Control Panel. The terminal strips are labeled TBW1 to TBW8.
Reader channel one corresponds to TBW1, Reader channel two corresponds to TBW2, and so on.
3d. Wiegand terminal strips accept up to 18AWG wire. Use the small screwdriver provided to secure each wire
into its terminal strip location. The terminal strips are removable to facilitate attaching the signal wires. Their
signal names are marked on the Controller board, near each connector. See MultiProx Controller -
Connectors, Relay and Jumper Positions Figure 4. The terminal strip connections are also shown in the
following table:
TBW(1-8) PIN NUMBER SIGNAL TYPICAL WIRE COLOR
1 DATA “0” GREEN
2 DATA “1” WHITE
3 DATA RETURN DRAIN WIRE
4 GREEN LED ORANGE
5 RED LED BROWN
6 BEEPER YELLOW
4. Configure the DIP switches SW1 SW2, SW3 and SW4
Note: Following each change of dip switch settings for SW1, SW2, SW3 or SW4, the unit must be reset by
powering down then up again before the new switch setting will take affect.
4a. See the Schlage/Westinghouse Card description diagram - Figure 2. To identify the card type, count the
number of digits printed on the SE card. 5 digit card numbers are 1030’s, 6 digit cards are 1040’s, and 8 digit
are 1050’s. Select Card Type on SW4, switch 6 and 7 for either 1030, 1040 or 1050. 1050 is the default
setting. See the MultiProx Switch settings - Figure 3.
4b. If the card type is 1050, ignore the Main facility, Alternate facility and Card letter switch settings and go to
paragraph (4d). If the type of card is a 1030 or 1040, set the Main Facility Code Letter on SW4 switch 2
and 3 and Main Facility Code Number on SW4 switch 1 and SW3 switch 1-8. The switches are to be set for
the binary representation of the facility code number printed on the cards. See the MultiProx Switch
settings Figure 3 and the Decimal to Binary Conversion Chart - Figure 9.