Version 5.3 Upgrade Procedure
1-12
SE 6000 Security Management System
message, (3) errors on 6000 IDS, ie bad type in type conversion, (4) Key Not In Memory when
record stored, (5) keyholder field length problems, and (6) report printer problems.
n All software for 6000 IDS needs to be tested on picture calibration. This must be run more
than once to make sure that previous calibration files are correctly overwritten, since 6000
IDS software that is currently shipping has a problem calibrating the second time.
n Code is present for reader access on an Access Code. When the Time Code is deleted the
Time Code parameter (TIMES) becomes NUL in the Time Field of the reader access (second
page) for Access Codes. The problem is that if a Master Access Report is generated, the
Report fails due to the NUL Time Field. Do not allow deletion of a Time Code if the Time
Code is present on the reader access TIMES for the Access Code.
n Monitor/Task. System does not provide SILENCE possibilities: (Client uses Building Mode
for alarm system functions). Note: SILENCE is the only command to reset latched contact.
Add Softkey to Monitor screen or Alarm Service to SILENCE the ACU.
n MAP function does not work - cannot draw maps. Cannot draw maps on consoles of systems
> 6100, due to SCO CGI memory allocation. Need Reflections (or X-) Terminal to run maps.
n Time code programming changes when viewed from Event Entry screen, eg Sunday always
displays Y regardless of programming - it seems that day fields are shifted by 1.
n When time code is deleted, opto relays drop out.
n Cannot assign a Report to a point entry over 15 for an 818SC (or NexSentry) ACU. Both ACU
types have Report capability up to 32. (808S/SN/SX/SXT have Reports only up to 15.)
n 6000 FRS systems have 2 partitions: / and /users. The RDI links request file to /tmp/request
from /users/stm/hostdata/request. Unix will not link across partitions, thereby causing RDI
program to fail. Also problem with multiplicity of system parameters, ie 840mb, 1.2gb IDE and
2.1gb SCSI. Needs to be addressed as BOM issue. Use temporary directory in /users for
request file link.
n When performing parking ticket editing, the operator zooms to the keyholder entry screen
and finds keyholder entry. When the operator returns to the ticket entry screen, the keyholder
ID number has been placed in the key number field. System should return key number, not
keyholder ID.
n Shunt requested on 4100 door results in point AND device shunt on 6000 monitor screen.
n Monitor status does not update to manual lock if door was in auto-unlock state and manually
locked is requested. (???? displays in the status screen.) When returned to auto-unlock by
requesting unlock, screen displays man-unlock instead of auto-unlock. If shunted and
unshunted it returns to the correct status - auto-unlock.
n Diagnostic unify programs were not on build tape. After the build, the programs were missing
from /users/atm/asql/diag. Customer Service needs these programs to diagnose database
problems.